Product center Explosion-proof fan CBF-Explosion-proof Axial Fan Series

CBF-Explosion-proof Axial Fan Series



Explosion-proof axial flow fan: CBF-300 CBF-400 CBF-500 CBF-600 CBF-700 CBF-750 series


It is suitable for conveying flammable, explosive and non-corrosive gas. The ambient temperature should not exceed 60 ℃. It is widely used in general factories, warehouses, offices, and houses for ventilation or strong heating. Installed in series to increase the pressure in the pipeline, removing the motor can be used as a free fan. ,采用防腐材料外涂环氧漆加工而成,电机采用特种防腐电机用于输送有腐蚀性气体。 Anti-corrosion axial flow fan (FT35-11 type) , which is made of epoxy paint with anti-corrosive material, and the motor adopts special anti-corrosion motor to transport corrosive gas. ( BT35-11型 ),用于输送易燃易爆的气体。 Explosion-proof axial flow fan ( BT35-11 ), used to transport flammable and explosive gases. It is suitable for the temperature group T1 ~ T4. The impeller is made of aluminum alloy to prevent sparks during operation. The motor is an explosion-proof motor. The performance parameters and dimensions of FT35-11 and BT35-11 fans are the same as T35-11 fans. The fan needs to have bracket feet and motor voltage. Please specify when ordering.
安装说明 Installation instructions for BT35-11 series explosion-proof axial fan
1. Check the fan for damage and deformation before installation. If there is any damage and deformation, do not install it until it is repaired properly.
2. When installing, pay attention to check whether the connecting parts are loose, and the gap between the blade and the wind cylinder should be even, and they should not collide.
3. The weight of the duct connected to the tuyere should not be borne by the fan of the fan, and additional support should be added during installation.
4. A wind collector must be installed at the fan outlet and hope to install a protective net.
5. The fan base must be naturally engaged with the ground plane. Do not tap the base to force the connection to prevent deformation of the base. During installation, the base should be corrected, iron pads should be maintained, and the horizontal position should be maintained. Then the foundation bolts should be tightened.
6. After the installation is completed, the experiment must be performed first, and the official use is allowed after the operation is normal.
Technical Parameters
Explosion-proof mark: Eed II BT4
Protection level: IP54
Anticorrosion grade: WF1
Rated voltage: AC220 / 380
Spindle speed: 1450r / min
Performance table of BT35-11 explosion-proof flame-retardant axial flow fan
Machine number
Spindle speed
Blade angle deg
Air volume
Full pressure mmHg
Full pressure efficiency
(A) with motor
(Two) with motor
model
power
model
power
4
1400
15
2323
7.3
0.87
YB801-4
0.55
BJO2-11-4
0.6
20
3053
8.2
0.88
YB801-4
0.55
BJO2-11-4
0.6
25
3785
8.4
0.895
YB801-4
0.55
BJO2-11-4
0.6
30
416
9.0
0.88
YB801-4
0.55
BJO2-11-4
0.6
35
4515
11.3
0.86
YB801-4
0.55
BJO2-11-4
0.6
4.5
1400
15
3309
9.3
0.87
YB801-4
0.55
BJO2-11-4
0.6
20
4349
10.4
0.88
YB801-4
0.55
BJO2-11-4
0.6
25
5389
10.7
0.895
YB801-4
0.55
BJO2-11-4
0.6
30
5861
11.5
0.88
YB801-4
0.55
BJO2-11-4
0.6
35
6428
14.3
0.86
YB801-4
0.55
BJO2-11-4
0.6
5
1400
15
4538
11.6
0.87
YB801-4V
0.55
BJO2-11-4
0.6
20
5965
12.9
0.88
YB801-4
0.55
BJO2-11-4
0.6
25
7291
13.1
0.895
YB801-4
0.55
BJO2-11-4
0.6
30
8040
14.2
0.88
YB801-4
0.55
BJO2-11-4
0.6
35
8818
17.6
0.86
YB801-4
0.55
BJO2-11-4
0.6
5.6
1400
15
6368
14.4
0.88
YB90S-4
1.1
BJO2-12-4
0.8
20
8368
16.0
0.895
YB90S-4
1.1
BJO2-12-4
0.8
25
10369
16.5
0.88
YB90S-4
1.1
BJO2-22-4
1.5
30
11279
17.7
0.86
YB90S-4
1.1
BJO2-22-4
1.5
35
11405
22.1
0.87
YB90S-4
1.1
BJO2-22-4
1.5
5.6
960
20
5730
7.5
0.87
YB90S-6
0.75
BJO2-21-6
0.8
25
7101
7.7
0.88
YB90S-6
0.75
BJO2-21-6
0.8
30
7724
8.3
0.895
YB90S-6
0.75
BJO2-21-6
0.8
35
8471
10.3
0.88
YB90S-6
0.75
BJO2-21-6
0.8
6.3
1400
20
11919
20.3
0.86
YB100L1-4
2.2
BJO2-31-4
2.2
25
14770
20.9
0.87
YB100L1-4
2.2
BJO2-31-4
2.2
30
16065
22.5
0.88
YB100L1-4
3
BJO2-32-4
3
6.3
960
15
6219
8.6
0.895
YB90S-6
0.75
BJO2-21-6
0.8
20
8173
9.6
0.88
YB90S-6
0.75
BJO2-21-6
0.8
25
10128
9.8
0.86
YB90S-6
0.75
BJO2-21-6
0.8
7.1
1420
20
17061
26.6
0.87
YB100L1-4
2.2
BJO2-31-4
2.2
25
21140
27.2
0.88
YB100L1-4
2.2
BJO2-31-4
2.2
30
22994
29.3
0.895
YB100L2-4
3
BJO2-32-4
3
7.1
910
15
8438
9.9
0.87
YB90S-6
0.75
BJO2-21-6
0.8
20
11091
11.1
0.88
YB90S-6
0.75
BJO2-21-6
0.8
25
13743
11.2
0.895
YB90S-6
0.75
BJO2-21-6
0.8
25
14948
12.0
0.88
YB90S-6
0.75
BJO2-21-6
0.8
30
16395
15.0
0.86
YB90S-6
0.75
BJO2-21-6
0.8







Copyright © 2018 Yueqing Sannuo Explosion-proof Electric Co., Ltd. All Right Reserved.

Zhejiang ICP No. 18003199-1  

24-hour customer service hotline: 18368700777 Tel: 0577-62826718 Fax: 0577-62826717

Address: Dongyan Industrial Zone, Wengyang Street, Yueqing City, Zhejiang Province Website: 33pp145.cn

Explosion-proof box Explosion-proof control box Explosion-proof air-conditioning LED Explosion-proof lamp Explosion-proof operation column

Technical Support: Youdou Software

Zhejiang Public Network Security Preparation No. 33038202003255
Scan your phone
Scan and add me on WeChat